EXTERIOR LAMP — Back-up Lamp/Wiring Diagram
EL-49wiring diagramCircuit has two paths: (A) A/T model uses Inhibitor Switch in R position to activate back-up lamps; (M) M/T model uses a dedicated Back-up Lamp Switch. Both share common fuse block (10A fuse), S.M.J., and lamp connections for R.H. and L.H. back-up lamps.
Back-up Lamp/Wiring Diagram
Components (14)
INHIBITOR SWITCHIGNITION SWITCHFUSE BLOCKS.M.J.Connector E101Connector M11Connector E17Connector E202Connector M101Connector M125BACK-UP LAMP SWITCHBACK-UP LAMP R.H.BACK-UP LAMP L.H.BODY GROUND
Connections (12)
FUSE BLOCK
FUSE BLOCKS.M.J.G/W— Via Engine room harness, connector E101 pin A8 / M11 pin A8
FUSE BLOCKS.M.J.G/L— Via connector E101 pin M9 / M11 pin M9
FUSE BLOCKS.M.J.G/W— Via connector E101 pin 19 / M11 pin 19
IGNITION SWITCH
IGNITION SWITCHFUSE BLOCK— 10A fuse
S.M.J.
S.M.J.BACK-UP LAMP R.H.G/W— Pin B
S.M.J.BACK-UP LAMP L.H.G/W— Pin B
INHIBITOR SWITCH
INHIBITOR SWITCHS.M.J.G/L— A/T model; engine room harness
INHIBITOR SWITCHS.M.J.G/W— A/T model; engine room harness
Connector E202
Connector E202BACK-UP LAMP SWITCHG/W— M/T model; engine room harness no. 2
Connector E202BACK-UP LAMP SWITCHG/L— M/T model; engine room harness no. 2
BACK-UP LAMP R.H.
BACK-UP LAMP R.H.BODY GROUNDB— Ground
BACK-UP LAMP L.H.
BACK-UP LAMP L.H.BODY GROUNDB— Ground
NOTE
(A) : A/T model
(M) : M/T model
S.M.J. [Refer to last page (Foldout page).]
FUSE BLOCK (Refer to 'POWER SUPPLY ROUTING'.)
See also
POWER SUPPLY ROUTING · Foldout page (S.M.J.)