Nissan 200SX S13 silhouetteS13

BATTERY — Battery Test and Charging Chart (Cont'd) — A: SLOW CHARGE

EL-14flowchart

Initial charging-current table conflates pairs of battery types per row (e.g. 28B19/34B19) since the initial-current value is identical.

Battery Test and Charging Chart (Cont'd)

A: SLOW CHARGE

Slow charge — procedure flow

1
Determine initial charging current from specific gravity referring to Fig. 2.
2
Charge battery. Check charging voltage 30 minutes after starting the battery charge.
Below 12 volts or above 15 volts
3
12 to 15 volts
O.K.
4
Continue to charge for 12 hours.
5
CHECKING SPECIFIC GRAVITY. Refer to "Specific Gravity Check".
6
Conduct additional charge as per Fig 3, if necessary.
7
Go to "CAPACITY TEST".

Fig. 2 — Initial charging current setting (Slow charge)

28B19R(L) / 34B19R(L)
Converted SG below 1.100 — Initial charging current (A)4.0
46B24R(L) / 55B24R(L)
Converted SG below 1.100 — Initial charging current (A)5.0
50D23R(L) / 55D23R(L)
Converted SG below 1.100 — Initial charging current (A)7.0
65D26R(L) / 80D26R(L)
Converted SG below 1.100 — Initial charging current (A)8.0
75D31R(L)
Converted SG below 1.100 — Initial charging current (A)9.0
95D31R(L) / 95E41R(L)
Converted SG below 1.100 — Initial charging current (A)10.0
130E41R(L)
Converted SG below 1.100 — Initial charging current (A)14.0

Fig. 3 — Additional charge (Slow charge) by current SG band