STARTING SYSTEM — Starter — Brush Holder / Pole Piece / Armature Check
EL-22prose procedureBrush holder shown for both starter variants (M1T71481 fig1, S114-523 fig2).
Brush Check (Cont'd)
BRUSH HOLDER
Brush holder — insulation + free-movement check
- 1Perform insulation test between brush holder (positive side) and its base (negative side). Continuity exists → Replace.
- 2Check brush to see if it moves smoothly. If brush holder is bent, replace it; if sliding surface is dirty, clean.
Pole Piece Check
NOTE
Pole piece is secured to yoke by bonding agent. Check pole piece to see that it is secured to yoke and for any cracks. Replace malfunctioning parts as an assembly. Holder may move slightly as it is only inserted and not bonded.
Armature Check
Armature — continuity + insulation tests
- 1Continuity test (between two segments side by side). No continuity → Replace.
- 2Insulation test (between each commutator bar and shaft). Continuity exists → Replace.