Trouble Diagnoses — Diagnostic Procedure 11 (Cont'd)
EF & EC-105flowchartDiagnostic Procedure 11 (Cont'd)
1
INSPECTION START
2
Perform switch ON/OFF diagnosis (in Mode IV).
O.K.
INSPECTION END
N.G.
3
CHECK INPUT SIGNAL.
1) Disconnect starter motor "S" terminal.
2) Turn ignition switch "START"
3) Check voltage between terminal 43 and ground.
Voltage: Battery voltage
If N.G., repair harness and connectors.
N.G.
Check the following items:
Check the following items:
1) "10A" fuse and "G" fusible link
2) Ignition switch
3) Middle harness connector
O.K.
INSPECTION END