VACUUM PIPING — Removal and Installation, Inspection
BR-10parts diagramRemoval and Installation
CAUTION
Do not apply any oil or lubricants to vacuum hose and check valve.
IMPORTANT
Insert vacuum tube into vacuum hose more than 24 mm (0.94 in).
Install check valve, paying attention to its direction.
Inspection
HOSES AND CONNECTORS
Check vacuum lines, connections and check valve for airtightness, improper attachment, chafing and deterioration.
| Specification | Value |
|---|---|
| Minimum vacuum tube insertion depthTube into vacuum hose. | More than 24mm (0.94 in) |
Minimum vacuum tube insertion depthTube into vacuum hose.
More than 24mm (0.94 in)