Nissan 200SX S13 silhouetteS13

SERVICE PROCEDURES — Refrigerant Lines (L.H.D. Model)

HA-30parts diagram

Refrigerant Lines — L.H.D. MODEL

Refrigerant-line tightening torques (with wrench-size markers)

A
Wrench size (mm)24/27
N·m20 - 29
kg-m2.0 - 3.0
ft-lb14 - 22
Applies toCooling-unit suction-line flare; expansion-valve outlet
B
Wrench size (mm)22/24
N·m15 - 25
kg-m1.5 - 2.5
ft-lb11 - 18
Applies toHigh-pressure discharge service valve
C
Wrench size (mm)17/19
N·m10 - 20
kg-m1.0 - 2.0
ft-lb7 - 14
Applies toReceiver-drier inlet/outlet flares
Wrench size (mm)
N·m13 - 16
kg-m1.3 - 1.6
ft-lb9 - 12
Applies toCondenser-to-receiver-drier connection [?]
Wrench size (mm)
N·m3 - 4
kg-m0.3 - 0.4
ft-lb2.2 - 2.9
Applies toDual-pressure switch on receiver drier
Expansion-valve fittings (top-left inset)
Wrench size (mm)
N·m10 - 20 / 15 - 25 / 20 - 29
kg-m1.0 - 2.0 / 1.5 - 2.5 / 2.0 - 3.0
ft-lb7 - 14 / 11 - 18 / 14 - 22
Applies toThree expansion-valve flare-nut sizes